BRAND | Hioki |
Product | RM3545-02 |
Description | Resistance Meter |
Internal code | ONR4763130 |
Technical specification | Resistance range 10 mΩ (12.00000 mΩ display Max., 10 nΩ resolution) to 1000 MΩ range (1200.0 MΩ display Max., 100 kΩ resolution), 12 steps [LP ON] 1000 mΩ (1200.00 mΩ display Max., 10 µΩ resolution) to 1000 Ω range (1200.00 Ω display Max., 10 mΩ resolution), 4 steps Measurement accuracy: ±0.006 % rdg. ±0.001 % f.s. Testing current 1 A DC to 1 µA or less [LP ON] 1 mA to 5 μA DC Open-terminal voltage 20 V DC (10 kΩ range or more), 5.5 V DC max. (1000 Ω range or less) [LP ON] 20 mV DC max. Temperature measurement -10.0°C to 99.9°C, accuracy: ±0.50°C (Temperature Sensor Z2001 and RM3545 combined accuracy), -99.9°C to 999.9°C (analog input) Measurement speed FAST (2.2ms) / MED (50Hz: 21ms, 60Hz: 18ms) / SLOW1 (102ms) / SLOW2 (202ms) Functions Temperature correction, temperature conversion, offset voltage compensation (OVC), comparator (ABS/ REF%), BIN, key-lock (OFF, menu lock, all lock), display digit count selection function (7- digit/ 6-digit/ 5-digit), automatic power supply frequency settings (AUTO/ 50Hz/ 60Hz), scaling, judgment sound setting, auto hold, averaging, statistical calculations, panel store/panel load, D/A output. Multiplexer [Only RM3545-02] Support Unit: Z3003 (Install up to 2 units) Communication interfaces Select from GP-IB (RM3545-01 only), RS-232C, Printer (RS-232C), or USB . Remote function, communications monitor function, data output function, memory (50) Power supply 100 V to 240 V AC, 50 Hz/60 Hz, Rated power consumption: 40 VA max. Dimensions and mass 215 mm (8.46 in) W × 80 mm (3.15 in) H × 306.5 mm (12.07 in) D [RM3545/RM3545-01] 2.5 kg (88.2 oz), [RM3545-02] 3.2 kg (35.3 oz) |
Please Contact Us to Order to offer competitive prices and delivery time for Hioki - RM3545-02 Resistance Meter number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Peru Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Infrared Thermometer
Calibration certificate for Hioki FT3700-20
Factory Calibration Certificate - No Data
TERMINAL PROBE
clamp on leak hitester
3196 obsolete replaced by PW3198-90
Power Quality Analyzer
3197 obsolete replaced by PQ3100-01
Power Quality Analyzer
ac/dc clamp meter
Resistance Meter
Power Quality Analyzer
9029 obsolete, no repacement, possible alternative DT4253 Digital multimeter with DT4910 K
Temperatur sensor
Clamp Datalogger
Data transfer adapter
3540 (obsolete/replaced with RM3548)
HiTester
Pin Type Lead
Test Device
battery tester
Power analyzer
Clamp
4-terminal probe
Power Quality Analyzer
Clamp Meter with DCV
torq wr 3/4in mech fix 120-600
Voltage Logger
Voltage Logger
POWER ANALYZER
POWER ANALYZER